Air source heat pump with heat recovery PURY-P Series PURY-(E)P Y(S)NW-A2(-BS) Next Stage R2 Line
Line R2 Next Stage
The R2 NEXT Stage line boasts an optimized compressor with multi-port technology, a new design, advanced features, and enhanced controls.
ErP Compliant
Mitsubishi Electric products comply with the Ecodesign Directive with the minimum requirements imposed in order to ensure transparent and environmentally friendly design.
All products that reflect the Ecodesign Directive declare the efficiency used by the products to define the actual energy consumption.
R2 Next Stage Line
The R2 Next Stage line encompasses product ranges that are simultaneous two-pipe cooling/heating systems with heat recovery and continuous heating.
R410A
The Mitsubishi Electric product works with refrigerant gas R410A.
Technical sheet
New design
The new outdoor units of the YNW series use a four-sided heat exchanger close to the top of the case near the fan. This technological and construction choice makes it possible to increase heat exchange efficiency

Energy saving
Energy efficiency has been further improved compared to YLM units and now hits top of the range performance values. SEER values have been raised by 139% (P500) compared to the previous model and SCOP values by 49% (P300 and P500). This allows the new YNW units to consume less energy in both cooling and heating. All year-round saving.

New fan with new blade profile
The fan of the new YNW series has been completely redesigned to fit with the new four-sided battery. The profile of the fins has been optimised to minimise fluid flow losses.

SIngle module

Advanced “Low Noise” function
Low noise” mode can now be selected using five different settings: 85%, 70%, 60% and 50% (values referring to ventilation speed). Noise reduction is directly configurable from the control board of the outdoor unit. Different settings can be selected depending on the installation requirements (in applications with special noise constraints).

New BC distributor
Increased number of connections (for systems with BC SUB distributor) and increased geometric limits. In the R2 heat recovery systems of the new YNW line, up to 11 BC SUB distributors can be connected to the BC Main distributor, thus allowing greater flexibility of configuration. The adoption of the new architecture allows a reduction of the refrigerant charge in the system.

Mitsubishi Electric puts the best professionals at your service to advise you in your choice and guide you through all the steps of purchase and installation.
Find a resellerYour home is unique and deserves a perfect solution. Can we help you find yours?
Let us suggest you