Air source heat pump PUHY-P-YNW-A2.

Serie
PUHY-P

Line Y Next Stage

Ideal for large destinations, with power available up to 54 Hp
Possibility of dual configuration in Air-to-Air PdC version with connection to indoor air units of CITY MULTI range and residential/commercial range via LEV KIT, it is also available in Air-to-Water PdC version with connection to low and high temperature hydronic modules of CITY MULTI range for water heating and cooling
Settable fan head up to 80 Pa
Image
Nr.50 unità
no. 50 indoor units max
Image
Potenza
Power from 22.4 kW to 150 kW
Image
Gas R410a
Refrigerant Gas R410A
Image
raffrescamento acqua
Water cooling
Image
Raffrescamento ad aria
Air cooling
Image
riscaldamento acqua
Water heating
Image
Riscaldamento aria
Air heating
Image
Temperatura esterna
Temp. Outdoor Minimum -20°C

The Y Line Next Stage

.

The Y Next Stage line adopts a two-pipe refrigerant system, which allows the system to transition from cooling
to heating and vice versa, ensuring that a high level of comfort is maintained in all zones. Each outdoor
compact uses R410A refrigerant and an inverter-driven compressor for effective control of the energy used

.

Technical sheet

Expand all | Collapse all

The heat exchange coil of the outdoor unit is divided into two portions. Even if defrosting becomes necessary, the system can continue to operate using one of the two portions of the coil while the other portion is defrosted.

Image
003.jpg

With combined modules, the system performs defrosting alternately on the different modules that make up the system. In this way, while one module is defrosting the other(s) can (can) continue to deliver heat output to the room.

Image
004.jpg

In a conventional system, the evaporation temperature is kept constant regardless of the system load conditions. Under low-load conditions (when the heat loads to be coped with are limited), increasing the evaporating temperature of the system makes it possible to decrease the work to be done by the compressor and consequently limit the electrical absorption of the outdoor unit without affecting the comfort level in the room.

Image
005.jpg
Image
006.jpg

The new outdoor units are equipped with the function for selecting the evaporating temperature that automatically takes into account the system load conditions.

Image
007.jpg

The evaporation temperature can be changed by an external contact (with PAC-SC36NA-E accessory).

Image
008.jpg

"Low noise" mode can now be selected based on 5 different settings: 85%, 70%, 60% and 50% (values referring to fan speed). Noise attenuation is directly configurable from the control board of the outdoor unit (optional PAC-SC36NA connector required). Different settings can be chosen based on installation requirements (in applications with special noise constraints).

Image
009.jpg

The static pressure of the outdoor unit fan can be set between 0-30-60 and 80 Pa. This facilitates installation of the unit even in locations that require ducting of exhaust air from the fan.

Image
0010.jpg

In certain types of installation and in areas with high building density, the passage of air can be obstructed. Under very high outdoor temperature conditions and if the air expelled by the unit's fan is not properly moved away the air can stagnate and cause the air temperature around the unit to rise. Thanks to the extended operating range of up to 52°C, the system is able to continue operating without interruption even under these conditions.

The "Auto-shift" mode is a new operating mode that can be set by external unit and is in addition to the two existing modes: COP Priority mode (system operates by maximizing efficiency) and Capacity Priority mode (system operates by maximizing power output). This new operating mode allows the system to operate in Capacity Priority mode for the first 30 minutes and then switches operation to COP Priority mode. Due to this, the system speeds up the regulation time. This mode is an advantage especially during the start-up of the air conditioning system (e.g., when restarting the system early in the morning).

Image
0012.jpg

The new YNW outdoor units are equipped with the Preheat defrost function (which can be activated from the outdoor unit) that increases the air supply temperature before the system performs defrosting operations (typically during defrosting, indoor units deliver air at a lower temperature) so as to "calm" the slight temperature drop in the room during defrosting.

Image
0013.jpg

Combined Modules of CITY MULTI outdoor units provide an excellent level of reliability with the new Emergency (Backup) function, which can be easily activated from the remote control of any indoor unit in case of system malfunction. The emergency function guarantees an average cooling and heating operation of 4 hours.

Image
0014.jpg

Combination modules of CITY MULTI outdoor units employ an automatic routine called "Rotation Function," so as to ensure a balance of outdoor unit utilization and consequently an optimal life cycle for all system components.

Image
0015.jpg
Ready to buy?

Mitsubishi Electric puts the best professionals at your service to advise you in your choice and guide you through all the steps of purchase and installation.

Find a reseller
Need help?

Your home is unique and deserves a perfect solution. Can we help you find yours?

Let us suggest you

A newsletter about air conditioning

Dedicated to private individuals and professionals who want to stay informed about the latest in the industry: technologies, innovations, regulations, and opportunities.